  diesel generator set air ch arge- air c ooling 650 kva / 50 hz / standby (fuel-optimized) 380 - 415v (reference dp590d5s C fuel optimized and dp590d5s C exhaust optimized for prime rating technical data) sy ste m r atings ? standby ds650d5s ds650d5s ds650d5s voltage (l-l) 380v 400v 415v phase 3 3 3 pf 0.8 0.8 0.8 hz 50 50 50 kw 520 520 520 kva 650 650 650 amps 988 938 904 generator model 573rsl7733 573rsl7733 573rsl7733 temp rise 150 c/40c 150 c/40c 150 c/40c connection 4 lead wye 4 lead wye 4 lead wye // low installation cost // best fuel consumption values // long maintenance intervals // h igh-effciency components // best-in-class reliability and availability b enefits optional equipment shown. standard equipment may vary. ? power available up to 40c/400 m
2 /// / 50 hz 650 kva // engine air cleaners oil pump oil drain extension & s/o valve full fow oil flters c losed crankcase ventilation jacket water pump thermostat exhaust manifold C dry blower fan & fan drive radiator C unit mounted electric starting motor C 24v governor C electronic isochronous base C formed steel sae fywheel & bell housing c harging alternator C 24v flexible fuel connectors fuel system: common rail // customer interface smart connect // generator nema m g1, ieee and ansi standards compliance for temperature rise and motor starting vde 0530, iec 34.1, bs 5000, c sa c 22.2-100, as 1359 sustained short circuit current of up to 300% of the rated current for up to 10 seconds self-ventilated superior voltage waveform digital, solid state, volts-per-hertz regulator no load to full load regulation brushless alternator with brushless pilot exciter 4 pole, rotating feld 150 c maximum standby temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing 0.25% voltage regulation 100% of rated load C one step 3% maximum harmonic content insulation class h protection class ip20 standard equip ment ? ? represents standard product only. consult factory/mtu onsite energy distributor for additional confgurations. // engine-generator set is designed and manufactured in facilities certifed to standards iso 9001:2008 and iso 14001:2004 // performance assurance c ertification (pa c) - engine-generator set tested according to iso 8528-5 for transient response - verifed product design, quality and performance integrity - all engine systems are prototype and factory tested // power rating - permissible average power output during 24 hours of operation up to 85% c ertific ations and standards
3 /// / 50 hz 650 kva // engine m anufacturer mtu model 12v1600g70f type 4-c ycle arrangement 12-v displacement/cylinder: l (cu in) 21 (1,281) bore: mm (in) 122 (4.8) stroke: mm (in) 150 (5.91) c ompression ratio 17.5:1 rated speed rpm 1500 engine governor electronic isochronous m ax power: kwm (bhp) 576 (772) speed regulation 0.25% air flter dry // lube oil capacity total oil system: l (gal) 73 (19.3) // electrical electric volts d c 24 c old cranking amps under -17.8c (0f) 1000 // fuel system fuel supply connection size ? m 22 x 1.5 male fuel return connection size ? m 16 x 1.5 male m aximum fuel lift: m (ft) 5 (16) recommended fuel see mtu fuids & lubrication spec. total fuel fow: l/hr (gal/hr) 341.8 (90.3) // fuel consumption standb y at 100% of power rating: l/hr (gal/hr) 129.8 (34.3) at 75% of power rating: l/hr (gal/hr) 99.9 (26.4) at 50% of power rating: l/hr (gal/hr) 69.6 (18.4) // cooling/radiator system standb y ambient capacity of radiator: c (f) 50 (122) m ax. restriction of cooling air, intake, and discharge side of rad.: kpa (in. h 2 0) 0,2 (0,803) water pump capacity: l/min (gpm) 433 (115) h eat rejection to coolant: kw (btum) 236 (13,421) h eat rejection to after cooler: kw (btu m ) 104 (5,914) h eat radiated to ambient: kw (btum) 59.4 (3,378) engine coolant capacity: l (gal) 65 (17,2) radiator coolant capacity: l (gal) 41 (10,8) c oolant to cooler temperature: c (f) 95 (203) // air requirements ? standb y aspirating: m 3 /min (scfm) 48 (1,695) air fow required for rad. cooled unit: m 3 /min (scfm) 803 (28,350) remote cooled applications; air fow required for dissipation of radiated gen-set heat for a max of 25f rise: m 3 /min (scfm) 216 (7,618) // exhaust system standb y gas temp. (stack): c (f) 484 (903) gas volume at stack temp: m 3 /min (cfm) 126 (4,450) m aximum allowable back pressure: kpa (in. h 2 0) 15 (60.2) applic ation data // the generator set complies to g2 // engine-generator set tested to iso 8528-5 for transient response // accepts rated load in one step per nfpa 110 // all engine-generator sets are protoype and factory tested // m tu onsite energy is a single source supplier // global product support // 2 year standard warranty // c ooling system 50c (integral set-mounted; engine driven fan) // 12v1600 diesel engine (21,0 liter displacement; common rail fuel injection; 4-cycle) // engine-generator resiliently mounted // c omplete range of accessories // brushless, rotating feld generator (p m g excitation; 300% short circuit capability; 2/3 pitch stator windings) // terminal box s tandard f eatures ? ? represents standard product only. consult factory/mtu onsite energy distributor for additional confgurations. ? air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 )
4 /// / 50 hz 650 kva subject to change. | 3236001 | edition 01/14 | en c 2014-02. mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com weigh ts and dimensions system dimensions (l x w x h) weight (dry) open power unit (opu) 3715 x 1900 x 2047 mm (146.26 x 74.80 x 80.59 in) 4545 kg (10,020 lbs) m aterials and specifcations subject to change without notice. weights and dimensions are based on open power units and are estimates only. c onsult the factory for accurate weights and dimensions for your specifc engine-generator set. drawing above for illustration purposes only, based an standard open power 400 volt engine-generator set. lengths may vary with other voltages. do not use for installation design. see website for unit specifc template drawings. sound data // c onsult your local m tu onsite energy distributor for sound data. emissions data // c onsult your local m tu onsite energy distributor for emissions data. r ating definitions and c onditions // standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 8528-1, iso-3046-1, bs 5514, as 2789 and din 6271. // deration factor: altitude: c onsult your local m tu onsite energy distributor for altitude derations. temperature: c onsult your local m tu onsite energy distributor for temperature derations.


▲Up To Search▲   

 
Price & Availability of DS0650D5S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X